Aluminum Wire
ER1100 Aluminum Welding Wire
ER1100 (Al99.0) is commercial pure aluminum filler wire for welding general 1xxx pure aluminum materials.
产品名称 ER1100
ALUMINUM WELDING WIRE
ER1100 (Al99.0) is commercial pure aluminum filler wire for welding general 1xxx pure aluminum materials.
Key Features: Stable pure aluminum composition, good electrical conductivity and outstanding general corrosion resistance. Caution: Low mechanical strength, not for load-bearing structural parts; not suitable for welding 5xxx/6xxx series aluminum alloys.
Applicable Standards
AWS A5.10 ER1100(MIG)/ R1100(TIG)
EN ISO 18273:S Al 1100(Al99.0)
Standard Diameter & Packaging
• MIG wires: 0.8/0.9/1.0/1.2/1.6 mm, Standard spools: 0.45kg, 0.5kg, 1kg, 2kg,6 kg, 7 kg
-TIG rods: 2.0/2.4/3.2/4.0/5.0 mm, 1m fixed length, packed in5kg plastic tube and 5kg cardboard box.
Welding Polarity
• MIG (GMAW):DCEP
• TIG (GTAW):AC
Shielding Gas (MIG + TIG)
• Preferred shielding gas: 100% pure Ar. Ar+He mixture is available for thick plates requiring deep penetration.
• Flow rate: MIG 18–25 L/min, TIG 12–18 L/min.
Mechanical Properties of Deposited Metal
• Tensile Strength: 70–98 MPa
• Yield Strength: 28–42 MPa
• Elongation (A5): 28%–38%
• Melting Range: 643–658℃
Key Advantages
• Good electrical conductivity, applicable for common conductive aluminum parts
• Excellent atmospheric and mild chemical corrosion resistance
• Uniform silver-white finish after anodizing with slight color difference
• Stable arc, low spatter and smooth weld bead
• Compatible with MIG and TIG, ideal for thin and medium pure aluminum sheets
Recommended Base Metals
✅ Recommended: 1100, 1050, 1060, 1070 commercial pure aluminum alloys ✅ Dissimilar welding: Various combinations of 1xxx pure aluminum materials
⚠️ Caution: Low tensile strength, cannot be used for stressed load-bearing structures
❌ Do not weld 5xxx magnesium-containing or 6xxx heat-treatable aluminum alloys, which will cause strength decline and poor corrosion resistance
Applications
• General conductive aluminum busbars, electrical cabinet conductive accessories
• Atmospheric corrosion-resistant equipment, ventilation aluminum ducts
• Food-grade aluminum containers and light storage tanks
• Thin aluminum decorative panels and heat dissipation shells
• General anti-corrosion lining and non-load aluminum housings
Common Welding Problem & Solutions
· Weld Porosity
Cause: Insufficient oxide cleaning, wet shielding gas, wind interference.