E410T1-1C Stainless Steel Flux Cored Welding Wire
E410T1-1C stainless steel flux cored welding wire is classified under AWS A5.22/A5.22M in the supplied test report. Available test data covers 1.2 mm wire, CO₂ shielding gas, chemical composition, and deposited metal mechanical properties for technical evaluation.
Key Specifications
Item | Specification |
|---|---|
Product Name | E410T1-1C Stainless Steel Flux Cored Welding Wire |
Classification | E410T1-1C, as stated in the inspection report |
Standard | AWS A5.22/A5.22M, as stated in the report |
Product Type | Stainless Steel Flux Cored Welding Wire |
Stainless Steel Family | Martensitic |
Wire Diameter | 1.2 mm |
Shielding Gas | CO₂ |
Tensile Strength Requirement | ≥ 520 MPa |
Actual Tensile Strength | 617 MPa |
Elongation Requirement | ≥ 20% |
Actual Elongation | 32% |
Bend Test | OK, according to the report |
X-ray Test | Grade I, according to the report |
Chemical Composition of E410T1-1C
Element | Requirement (wt.%) | Actual Result (wt.%) |
|---|---|---|
Carbon (C) | ≤ 0.12 | 0.05 |
Silicon (Si) | ≤ 1.00 | 0.42 |
Manganese (Mn) | ≤ 1.20 | 0.38 |
Sulfur (S) | ≤ 0.03 | 0.006 |
Phosphorus (P) | ≤ 0.04 | 0.02 |
Nickel (Ni) | ≤ 0.60 | 0.04 |
Chromium (Cr) | 11.0–13.5 | 12.76 |
Molybdenum (Mo) | ≤ 0.75 | 0.01 |
Copper (Cu) | ≤ 0.75 | 0.007 |
Mechanical Properties of Deposited Metal
Property | Requirement | Actual Result |
|---|---|---|
Tensile Strength | ≥ 520 MPa | 617 MPa |
Elongation | ≥ 20% | 32% |
Bend Test | OK | OK |
X-ray Test | Grade I | Grade I |
Welding Parameters for E410T1-1C
Parameter | Reported Value |
|---|---|
Wire Diameter | 1.2 mm |
Shielding Gas | CO₂ |
Welding Current | 140–240 A |
Welding Voltage | 22–23 V |
Applications and Material Selection
- Fabrication of compatible chromium stainless steel components
- Industrial equipment maintenance and repair
- Welding of suitable 410-series stainless steel parts
- Industrial applications requiring specified weld metal strength and hardness
How to Choose E410T1-1C Flux Cored Welding Wire
- AWS classification: Confirm that the complete product designation matches the project specification.
- Wire diameter: Check whether 1.2 mm or another available diameter is required.
- Shielding gas: Confirm CO₂ compatibility with the specified classification and welding procedure.
- Chemical composition: Review the applicable limits and batch inspection data.
- Mechanical properties: Confirm tensile strength, elongation, hardness, and other project-specific requirements.
- Welding procedure: Verify preheating, post-weld heat treatment, and inspection requirements where applicable.
Request a Quote for E410T1-1C Welding Wire
- Required AWS classification
- Wire diameter and order quantity
- Base material and welding application
- Applicable standard or project specification
- Required inspection documents or certificates